Sign In | Join Free | My himfr.com
Home > Protection Relay Testing >

High Fidelity Protection Relay Testing / 51 Overcurrent Relay K3040

Kingsine Electric Automation Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap High Fidelity Protection Relay Testing / 51 Overcurrent Relay K3040 from wholesalers
     
    Buy cheap High Fidelity Protection Relay Testing / 51 Overcurrent Relay K3040 from wholesalers
    • Buy cheap High Fidelity Protection Relay Testing / 51 Overcurrent Relay K3040 from wholesalers
    • Buy cheap High Fidelity Protection Relay Testing / 51 Overcurrent Relay K3040 from wholesalers
    • Buy cheap High Fidelity Protection Relay Testing / 51 Overcurrent Relay K3040 from wholesalers
    • Buy cheap High Fidelity Protection Relay Testing / 51 Overcurrent Relay K3040 from wholesalers

    High Fidelity Protection Relay Testing / 51 Overcurrent Relay K3040

    Ask Lasest Price
    Brand Name : Kingsine
    Model Number : K3040
    Certification : ISO9001,CE
    Delivery Time : 15 working days
    Payment Terms : T/T in advance ,L/C
    Supply Ability : 50 sets/ month
    • Product Details
    • Company Profile

    High Fidelity Protection Relay Testing / 51 Overcurrent Relay K3040

    High Fidelity Protection Relay Testing / 51 Overcurrent Relay K3040


    Relay protection test devices
    1.Easy test
    2.operation menu, Simple operation
    3.Nominal input voltage:220VAC
    4.Power:1000VA

    1. Unique self-protection system assure the powerful protection when instrument is operating, automatic stop the output when the network is abnormal ;
    2. Unique power switch and amplifier technology, so the output precision and power efficiency and factor are increased, which conforms to international tendency of energy save and environmental protection;
    3. With alarm function of housing grounding testing and external voltage input, to guaranty personal security;
    4. Two in one of meter and source, with function of both internal and external testing, self-calibration, oscillograph, and the duration of each oscillograph reaches 50S (optional function);
    5. Offer independent Aux. DC to tested devices, 0 ~ 300V/0.6A (Poleless and adjustable);
    6. Function of transducer and energy meter testing (optional function);
    7. Testing interface offer unique output monitoring function and Pre-curve-tracing function, helps more on the spot analysis;


    Technical Data of K3040


    Voltage generators

    Setting

    Range

    4-phase AC (L-N)

    4 x 0 ... 130 V

    2-phase AC (L-L)

    2 x 0 ... 260 V

    Power

    4-phase AC (L-N)

    4 x 70VA, at 0 ... 130 V

    2-phase AC (L-L)

    2 x 140VA, at 0 ...260 V

    Accuracy

    <0.07% reading + 0.03% range guaranteed

    at 0 ... 130 V

    <0.02% reading + 0.01% range typical

    at 0-130V

    Resolution

    1mV

    Current generators

    Setting

    Range

    3-phase AC (L-N)

    3 x 0 ... 40 A

    1-phase AC (2L-N)

    1 x 0 ... 80 A

    1-phase AC (3L-N)

    1 x 0 ... 120 A

    Power

    3-phase AC (L-N)

    3x 450VA , at 0 ... 40A

    1-phase AC (2L-N)

    1x 520VA, at 0 ... 80A

    1-phase AC (3L-N)

    1 x 1200 VA, at 0 ... 120A (Max.)

    Accuracy

    <0.07% reading + 0.06% range guaranteed at 0-40A

    <0.02% reading + 0.02% range typical at 0-40A

    Resolution

    1mA

    Generators, general

    Frequency

    Range

    0 ... 1000 Hz

    Accuracy / drift

    Error < 0.001Hz at 10 ... 65Hz,

    Error < 0.01Hz at 65Hz...450Hz

    Error < 0.02Hz at 450Hz...1000Hz

    Resolution

    0.001Hz

    Phase

    Range

    - 360° ... +360°

    Accuracy / drift

    Error < 0.2 °

    Resolution

    0.1°

    Timer

    Range

    Infinite

    Accuracy / drift

    Error<0.1ms

    DC generators

    Voltage ranges

    0 ... 300V/180W

    Current ranges

    0 ... 20A/300W

    Accuracy

    <0.07% reading + 0.03% range guaranteed at 0-300V

    <0.04% reading + 0.02% range typical at 0-300V

    <0.14% reading + 0.06% range guaranteed at 0-20A

    <0.05% reading + 0.02% range typical at 0-20A

    Resolution

    1mA; 1 mV

    Aux DC Supply

    Range

    0...300V/0.6A

    Binary inputs

    Number

    8 pairs

    Compatible Voltage

    10V ... 250V DC

    Binary outputs

    Number

    4 Pairs

    Capacity

    250V/3A AC/DC

    Synchronization

    Synchronization mode

    GPS

    Harmonic

    Harmonic overlap times

    2 ... 20 times

    Power supply

    Nominal input voltage

    220V AC±20%

    Power

    1000VA

    Nominal frequency

    47Hz….65Hz

    Environmental conditions

    Operation temperature

    -5°C ... 55 °C

    Storage temperature

    -20°C ... 75 °C

    Humidity range

    5% ... 90 %, non-condensing

    Weight

    20 KG

    Dimensions

    460(D)×140 (W)×360 (H) mm

    PC connection

    RJ45


    K30 Series Protection Relay Test Set:


    Model

    Channels

    AC Outputs

    K3063i / K3063Li

    10 output channels

    6*30A/3*40A/4*300V

    K3030i / K3030Li

    7 output channels

    3*30A/4*300V

    K3066

    13 output channels

    6*20A/3*40A/7*130V

    K3063

    10 output channels

    6*20A/3*40A/4*130V

    K3040

    7 output channels

    3*40A/4*130V

    K3030

    7 output channels

    3*30A/4*130V


    Major functions:


    Items

    IEEE(R) No.

    Synchronization relay

    Fault transplay

    GPS Synchronization

    Overcurrent relays

    50/76

    Inverse time overcurrent relays

    51

    Undercurrent relays

    37

    Ground fault relays

    50

    Directional overcurrent relays

    67

    Directional ground fault relays

    67N

    Overvoltage relays

    59

    Undervoltage relays

    27

    Directional voltage relays

    91

    Directional power relays

    32

    Power factor relays

    55

    Differential protection (differential circuits)

    87

    Distance protection equipment (phase by phase)

    21

    Negative sequence overcurrent relays

    46N

    Motor overload protection

    51/86

    Automatic reclosing devices

    79

    Tripping relays

    94

    Voltage regulating relays

    Overimpedance relays, Z>

    Underimpedance relays, Z

    Time-delay relays

    Quality High Fidelity Protection Relay Testing / 51 Overcurrent Relay K3040 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Kingsine Electric Automation Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)