Sign In | Join Free | My himfr.com
Home > Power Monitoring System >

ISO9001 Energy Management System Resolution for Power station service system

Kingsine Electric Automation Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap ISO9001 Energy Management System Resolution for Power station service system from wholesalers
     
    Buy cheap ISO9001 Energy Management System Resolution for Power station service system from wholesalers
    • Buy cheap ISO9001 Energy Management System Resolution for Power station service system from wholesalers
    • Buy cheap ISO9001 Energy Management System Resolution for Power station service system from wholesalers
    • Buy cheap ISO9001 Energy Management System Resolution for Power station service system from wholesalers
    • Buy cheap ISO9001 Energy Management System Resolution for Power station service system from wholesalers

    ISO9001 Energy Management System Resolution for Power station service system

    Ask Lasest Price
    Brand Name : Kingsine
    Model Number :
    Certification : ISO9001,CE
    Delivery Time : 15 working days
    Payment Terms : T/T in advance ,L/C
    Supply Ability : 50 sets/ month
    • Product Details
    • Company Profile

    ISO9001 Energy Management System Resolution for Power station service system

    System Summarized


    Power monitoring system software developed by Kingsine, use computer, communication device, monitoring and control unit, protection devices, etc. This provides a basic platform for real-time data etc.


    This electric system can provide “integration and monitoring” resolution. Major contains real-time power acquisition module, energy manage and analysis module, real-time history database. SOE module, SMS warning module. Powers monitoring system software plays a very important role and makes a very good power electrical management effect in electrical system, commercial and public building, infrastructure, automobile, petrochemical, telecommunications, metallurgy, light industry, water treatment and other fields.


    Applications Range:


    Industry distribution automatic system

    Substation automatic system

    Power station service system

    Energy efficiency management system

    Electrical engineering in intelligent

    Low voltage switch cabinet


    System Instruction


    1,Master layer

    Master layer contains:Power monitoring system software, monitor host, Database publishing service, Printer, UPS power groups. We have two ways: One server corresponding one client and one server corresponding multi-client. 

     

    2,Communication layer(communication device)

    Communication layer use Industrial switches and communication manager to achieve On-site monitoring and control device monitoring host connection.


    3,Spacer layer(On-site meter)

    Power quality monitoring device, PMC serial intelligent meter, Protection relay device and Transformer temperature controller install in spacer layer to achieve the functions as: on-site measurement, monitoring, communication, etc. PMC serials contains: PMC200 Multifunctional power meter, PMC180 Three-Phase Digital Power Meter, PMC180N Three-Phase Network Power Meter, PMC100 Single Phase Digital Power Meter, and PMC100N Single Phase Network Power Meter.


    PMC Series Product Selection Table


     Model

    PMC

    200

    PMC

    180Z

    PMC

    180P

    PMC

    180U

    PMC

    180I

    PMC

    180N

    PMC

    100Z

    PMC

    100P

    PMC

    100U

    PMC

    100I

    PMC

    100N

    Real-time Measure

    Phase

    voltage/line voltage/phase current

    Active power/reactive power/apparent power
    Power factor/frequency
    Active energy/reactive energy/apparent energy
    Power Quality Monitor
    Odd/even/Total Harmonic distortion
    Single Harmonic31times31times31times
    Single Harmonic active/reactive power
    Sequence component: Positive sequence/ Negative sequence/Zero sequence
    Unbalance degree
    Current K factor
    Voltage crest factor CF
    Overload nature/Phase sequence monitor/Phase angel difference
    Other Functions
    Energy multi-rate
    Max/Min/ Instantaneous value
    Phase current damand
    Active/reactive/apparent damand
    Over limit alarm
    SOE event record(with time scale)
    Display
    LCD
    LED Digital control panel
    Communication interface and protocol
    RS485/MODBUS
    RS232/MODBUSOption
    TCP/IP/MODBUSOption
    Profibus-DPOption
    Input/output (option)
    Binary input DI8-channel2-channel2-channel2-channel2-channel2-channel2-channel2-channel2-channel
    Relay output DO4-channel2-channel2-channel2-channel2-channel2-channel2-channel2-channel2-channel
    Analog intput AI2-channel
    Analog output AO2-channel1-channel1-channel1-channel1-channel1-channel1-channel1-channel1-channel1-channel1-channel
    Accuracy class
    Current/Voltage0.2 level0.5 level0.5 level0.5 level0.5 level0.5 level0.5 level0.5 level0.5 level0.5 level0.5 level
    Power0.5 level0.5 level0.5 level0.5 level0.5 level0.5 level
    Active Energy1.0 level1.0 level1.0 level1.0 level1.0 level
    Reactive Energy2.0 level2.0 level2.0 level2.0 level2.0 level
    Quality ISO9001 Energy Management System Resolution for Power station service system for sale