Sign In | Join Free | My himfr.com
Home > CT Analyzer >

Current Transformer KT210 CT PT Analyzer And Tester IEC60044-6

Kingsine Electric Automation Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Current Transformer KT210 CT PT Analyzer And Tester IEC60044-6 from wholesalers
     
    Buy cheap Current Transformer KT210 CT PT Analyzer And Tester IEC60044-6 from wholesalers
    • Buy cheap Current Transformer KT210 CT PT Analyzer And Tester IEC60044-6 from wholesalers
    • Buy cheap Current Transformer KT210 CT PT Analyzer And Tester IEC60044-6 from wholesalers

    Current Transformer KT210 CT PT Analyzer And Tester IEC60044-6

    Ask Lasest Price
    Brand Name : KINGSINE
    Model Number : KT210
    Certification : CE/ISO9001
    Price : negotiation
    Payment Terms : L/C, T/T
    Supply Ability : 100sets per month
    Delivery Time : 15 working days
    • Product Details
    • Company Profile

    Current Transformer KT210 CT PT Analyzer And Tester IEC60044-6

    Current Transformer KT210 CT PT Analyzer And Tester IEC60044-6

    Description of KINGSINE KT210 CT/PT Analyzer and Tester

    The KT210 CT/PT analyzer is designed for automatic testing and calibration of low leakage magnetic

    current transformers (CT without air gap core). It is suitable for use in the laboratory as well as for field

    use. It is Professional test equipment for current transformers used in the power industry.The KT210

    CT/PT analyzer can also be used to test and verify electromagnetic voltage transformers. The test

    items include PT excitation test, PT ratio and polarity test.

    Easy to operate CT / PT Analyzer,120V / 15A Current Output,9.7 inch touch screen operation,
    IEC60044-1, IEC60044-6, IEC61869-2, ANSI30/45 standard,High stability for bushing CT testing.

    Feature Of KINGSINE KT210 CT/PT Analyzer and Tester


    Voltage Measurement Input
    Secondary Input Range0~300V
    Max Knee point30KV
    Secondary Input Accuracy±0.1%
    Primary Input Range0~30V
    Primary Input Accuracy±0.1%
    Output
    Output Voltage0 Vac to 120 Vac
    Output Current0 A to 5 A (15 A peak)
    Output Power0 VA to 450 VA (1500 VA peak)
    Main Power Supply
    Input Voltage176 Vac to 264 Vac @ 10A Max
    Permissible Input Voltage120 Vdc to 370 Vdc @ 5A Max
    Frequency50 / 60 Hz
    Permissible Frequency47 Hz to 63 Hz
    ConnectionStandard AC socket 60320

    The following parameters testing for current transformers:

    Load measurement

    CT secondary winding resistance measurement

    CT excitation characteristic test

    CT ratio measurement

    CT fast ratio measurement

    Manually force demagnetize

    Phase and polarity measurement

    CT transient behavior measurement and analysis

    Automatic identification for unknown parameters CT

    Knee point voltage/current, 10% error curve, accuracy limit factor, apparatus safety factor,

    secondary time constant, residual magnetism factor, accuracy class, saturation and

    unsaturation, and inductance.

    The impedance / admittance of CT secondary Load, Like the burdens of various meters,

    relays, selector switches etc. are measured

    PT excitation characteristic test

    PT ratio test and polarity test.

    Specification Of KINGSINE KT210 CT/PT Analyzer and Tester

    AC/DC current input for wide range only, satisfy all power supply standard requested.
    Easy to operate, measure quickly, all test can be done automatically based on the same connection line type except overload impedance measurement.
    Adopt low voltage & variable frequency measurement method, it can test knee point voltage up to 30kV transformer as output max voltage only is 120V and max peak value current is 15A, high security.
    Portable design with light weight of 8kg, suitable for field test of electric power system, manufacturing factory of current transformer or laboratory to use.
    High measurement accuracy, resistance accuracy is 0.1%+1mΩ, phase accuracy±0.05 degree, variable accuracy is ±0.1% (1-5000 ), variable accuracy is ±0.2%(5000-10000).
    It can test current transformer according to IEC60044-1, IEC60044-6, IEC61869-2 and ANSI30/45 standard etc.
    Complete measurement function, it can test all type current transformer for secondary overload, secondary loop resistance, excitation characteristic, transient characteristic, ratio difference, angle difference and polarity. It can also test exact limit coefficient(ALF), device security coefficient(FS), secondary time constant(Ts), remanence coefficient(Kr), transient area coefficient(Ktd), inflexion voltage, current, level, saturation inductance, un-saturation inductance, 5% 10% error curve, of current transformer, hysteresis loop for current transformer, and evaluate test result according to defined standard.
    PT Test As for those inductive PT based on the definition of GB1207-2006(IEC60044-2), KT210 CT/PT Analyzer can also test them. KT210 CT/PT Analyzer can do variable ratio, polarity and secondary winding excitation test of inductive PT.



    Auto Demagnetizes

    Software-based tool to determine the residual magnetism in current transformers
    Analysis of the remanence condition before putting into operation the CT to assure proper function
    Simplifies power grid failure analysis after unwanted operation of protective relays
    Demagnetizes the CT core after measurement

    PC Control Available

    Full access to all functions of the KT210 via a PC using the RJ45 interface
    Optimizes the integration into automated testing procedures in production lines
    Data export into Word
    Customizable testing and reports

    Software of KT210 CT/PT Analyzer and Tester

    The software of KT210 is divided into PC software and CT Analyzer software, the interface and

    operation are almost same, and the only difference is that there is online command in the system

    option of CT Analyzer software. After the test finished, the test report can be guided or educed to

    check and operate.

    Note : one can use external keyboard to input in the writable frame when operate software , this is

    more convenient.

    KT210 CT/PT Analyzer software has the PC software and the inside software, theses two operating

    interface are basically the same except only somewhat different in the system interface. The System

    setting can set device IP, time, subject, help & etc.

    The system interface of PC software includes self-inspect, upgrade, system settings, calibration,

    Parameter;

    (part of equipment using instruction)


    F&A

    Q:1.What is your quality management system?

    A:Our quality is up to GB/T19001-2016/ISO9001:2015 standard,and we have the certificate

    Q: 2.What is your advantages?

    A: KINGSINE have been specializing in electric power testing & measurement for over 22 years. All-in-One design concept, high power burden & high output accuracy but with high cost-efficiency, 3-years guarantee of free repair and life-long maintenance.

    Q:3.How about your after-sales service?

    A: We are original manufacturer and always give best and soonest after-sales service.our chief engineer Mr.Terry had travelled to different countries for providing onsite technology support,and our sales managers always provide after-sales service positively.


    About US:

    Kingsine Electric Automation Co., Ltd. has been specializing in Research & Development, production and sales of Electric Testing & Measurement Instruments since 1999 foundation who is also honored as the High-tech enterprise certification and Software enterprise certificate recognized by China authority. With about high development speed every year, Kingsine win the Chinese top manufacturer for electric test equipmentin the domestic relay-tester market.China Guodian Corporation,State Grid Corporation of China,China Southern Power Grid Company Limited and many other national companies use our products.


    With ISO 9001:2008 certified Quality Management with R&D, Production and Marketing, now Kingsine's products are approved by over 70 countries worldwide in many industries of electrical power, metallurgy, petrochemical, railway mining and relative scientific research institution as well as same trade of meter and protective relays factories, and getting the warm welcome from the world large Electricity & Energy Exhibition such as POWER-GEN International of USA, Middle East Electricity of Dubai, HANNOVER MESSE of Germany and FIEE Electrical of Brazil. Its Relay-Tester is suitable working for many world famous relay protection devices such as ABB, SIMENS, ALSTOM, TOSHIBA, SCHNEIDER, AREVA, SEL, GE etc and Kingsine also give the full service with his distribution net from many countries partners of European, Asia and Middle East.

    Quality Current Transformer KT210 CT PT Analyzer And Tester IEC60044-6 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Kingsine Electric Automation Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)