    Brand Name : KINGSINE
    Model Number : K3130i
    Certification : CE/ISO9001
    Price : Negotiation
    Payment Terms : L/C,T/T
    Supply Ability : 100 sets/month
    Delivery Time : 15 working days
    • Product Details
    • Company Profile

    High Accuracy KINGSINE K3130i Protection Relay Testing Overcurrent Relay Test Kit

    High Accuracy KINGSINE K3130i Protection Relay Testing Overcurrent Relay Test Kit


    Discription of Overcurrent Relay Tester


    KINGSINE K3130i RELAY TEST is a portable field testing equipment with excellent performance; Elegance and polished appearance with aluminum alloy chassis and PC panel, within the ARM chip control, LCD screen display voltage and current output stopwatch, it could output a full isolation way for adjustable AC/DC voltage, and AC/DC current and a way for adjustable DC voltage; the output loop with double overload protection with large output capacity ,small volume,light weight, high reliability ,It Suitable for field calibration and test for various relay.


    Feature Of Overcurrent Relay Test Device


    All-in-One design, weight < 17.5kg;
    High Power & Accuracy with 3x35A & 4x310V analog outputs;
    Complying IEC61850 Sampling Value & GOOSE;
    The ever-expanding test library templates;
    Optional advance functions like energy meter and transducer calibration etc.

    7 Channels (3x35A & 4x310V) outputs, Each output channels are independent and simultaneous control of magnitude, Phase angle and frequency values, able to inject DC, AC sine wave and up to 60x harmonics.

    13 Low-level channels outputs up to 8Vac/10Vdc max.

    100/1000Mbit Fiber port for SMV and GOOSE simulations


    Specification Of Overcurrent Relay Test System


    Frequency & Phase Angle
    Frequency RangeDC~1KHz, 3KHz transient
    Frequency Accuracy±0.5ppm
    Frequency Resolution0.001 Hz
    Phase Range-360°~360°
    Phase Accuracy<0.02° Typ. / <0.1° Guar. 50/60Hz
    Phase Resolution0.001°
    Aux. DC Voltage Source (Battery simulator)
    Range0~350V @ 140W max
    Accuracy0.5%Rg Guar.
    Binary Input
    Quantity8pairs
    Typewet/dry, measurement
    Threshold10~600Vdc or potential free, Programmable
    Time resolution10us
    Sampling Rate10KHz
    Debounce time0~25ms (Software Controlled)
    Time rangeInfinite
    Time errors±1ms @ ≤1s, ±0.1% @ >1s
    Galvanic isolation4 isolated with each 2 pairs
    Binary Output (Relay Type)
    Quantity4pairs
    TypePotential free relay contacts, software controlled
    Break Capacity ACVmax: 400Vac / Imax:8A / Pmax:2500VA
    Break Capacity DCVmax: 300Vdc / Imax:5A / Pmax:150W
    Binary Output (Semiconductor Type)
    Quantity4pairs
    Type:Open-collector, Combination type female
    Break Capacity DC5~15Vdc / 5mA, 10mA max
    AC not permit
    Response time:100us

    Advantage Of Overcurrent Relay Test Kit

    Transducer Calibration Function:

    DC Measurement Input Hardware is ready, to be active
    Voltage InputRange0~±10V dc
    Max Input±11V dc
    Accuracy<0.05% rg Typ. <0.1% rg Guar.
    Input Impedance1M ohm
    Current InputRange0~±1mA / 1~±20mA, auto range
    Max Input600mA
    Accuracy<0.05% rg Typ. <0.1% rg Guar.
    Input Impedance15 ohm

    Energy Meter Calibration Function:

    Energy Meter Calibration Hardware is ready, to be active
    Sensor UsageMechanical meters / Electronic meters
    Sensor OutputHigh lever:>4.5V, Low level:<0.2V
    Pulse Input1 pulse input port, 5Vdc high level valid only.
    Pulse Range500KHz pulse input Max.
    Pulse Output1 Transistor output, Open-collector, 5Vdc/5mA

    F&A


    Q: 1. What is the lead time for delivery?
    A: It depends on the order quantity and the season you place the order.Usually we can ship within 7-15 days for small quantity, and about 30 days for large quantity.

    Q: 2. Do you have any MOQ limit?
    A: MOQ is 1 set. Please feel free to contact us for more detail.


    Q: 3.How long is the warranty period?

    A: We provide 3-years guarantee of free repair and life-long maintenance.

    Quality High Accuracy KINGSINE K3130i Protection Relay Testing Overcurrent Relay Test Kit for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Kingsine Electric Automation Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)